Ablative Boards

Fire Rated Mortar

Pipe Seals

Fire Rated Sealants

Linear Gaps/Joints

Fire Curtain/Pillows

Datasheets          

Installation Details

Safety Datasheets

Test Evidence

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Silverflame Pipe Wrap

Silverflame Pipe Sleeve

BA120 Intumescent Acrylic

Pyrocoustic Intumescent Acrylic

Silverflame ablative Sealant

Stopseal Fire Rated Silicone

Stopseal Putty

Stopseal Linear Gap Seal

Silverflame Expansion Joint

Flameshield Barrier

Stopseal Intumescent Pillows

FSI 101 Acetoxy Silicone

FSI 301 Neutral Silicone

FSI 501 Acrylic Sealant

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Flameshield Barrier

Stopseal Intumescent Pillows

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Silverflame Pipe Wrap

Silverflame Pipe Sleeve

BA120 Intumescent Acrylic

Pyrocoustic Intumescent Acrylic

Silverflame ablative Sealant

Stopseal Fire Rated Silicone

Stopseal Putty

Stopseal Linear Gap Seal

Silverflame Expansion Joint

Flameshield Barrier

Stopseal Intumescent Pillows

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Silverflame Pipe Wrap

Silverflame Pipe Sleeve

BA120 Intumescent Acrylic

Pyrocoustic Intumescent Acrylic

Silverflame ablative Sealant

Stopseal Fire Rated Silicone

Stopseal Putty

Stopseal Linear Gap Seal

Silverflame Expansion Joint

Stopseal Intumescent Pillows

Contact firestopit

Distributors

Installers

 
 

technical, material safety datasheets

Silverflame LUL Sealant


 

 

 

 

Reference number

LUL

 

Revision Date

26/07/2002

 

Revision number

004

 

1 - Substance Identification

 

Material / Trade name

Firestopit Silverflame LUL Sealant

 

Company Name

Firestopit.com Ltd
Swadlincote Road,
Woodville, Swadlincote,
Derbyshire. DE11 8DD

 

Telephone

+44 (0) 1283 229022

 

Fax

+44 (0) 1283 222219

 

2 - Composition

 
 

Water based sealant of acrylic emulsion plus fillers.

 

3 - Hazard Identification

 
 

None

 

Not classified as hazardous under CHIP regulations 1994/Amendments 1997

 

4 - First-aid Measures

 

Inhalation

Remove to fresh air and rest. If symptoms persist obtain medical advice.

 

Eyes

Irrigate with water for at least 15 minutes.

 

Skin

Rinse contaminated area with plenty of water. If irritation persists obtain medical attention

 

Ingestion

Wash out mouth with plenty of water. Give plenty of water to drink. Seek medical attention immediately.

 

5 - Fire Fighting Measures

 

Suitable Extinguishers

All standard fire-fighting media

 

Hazardous Decomposition

Oxides of Carbon

 

Special Exposure Hazards

Use self-contained breathing apparatus

 

6 – Accidental Release Measures

 
 

Wear suitable protective clothing: see section 8. Scoop up and place in container to wait transfer. Dispose of in accordance with local authority requirements.

 

7- Handling and storage

 
 

Wear suitable protective clothing (see section 8). Avoid contact with skin or eyes.

Store in a cool, dry, well-ventilated area, off the ground.
Avoid extremes of temperature.

 

8 – Exposure Control

 

Occupational Exposure Limit

None

 

Wear suitable gloves
Wear eye goggles if eye contamination likely

Cover skin and avoid skin contact

 

9 – Physical & Chemical Properties

 

Appearance

Viscous paste hardening to plastic solid

 

Colour

White.

 

Odour

Faint ether/alcohol

 

Relative Density

1.3 - 1.4

 

Viscosity

High

 

Solubility

Miscible in water

 

10 – Stability and Reactivity

 

Stability

Stable at normal temperatures

 

Hazardous Decomposition Products

None Known

 

11 – Toxicological Information

 

Health Effects

Slightly harmful if swallowed or allowed to contact skin.
May defat the skin

 

12 – Ecological Information

 
 

Not readily biodegradable.
No adverse biological effects foreseen

 

13 – Disposal Considerations

 
 

Allow waste to solidify. Dispose of in accordance with local authority requirements. Do not discharge into drains or watercourses

 

14 – Transport Information

 
 

No regulations apply for the transport of this material. Not classified as hazardous for road, rail, sea or air transport.

 

15 – Regulatory Information

 
 

Wear suitable protective coating
Wear suitable gloves
Wear goggles if eye contamination likely
 

The information contained in this document does not constitute the users own assessment of workplace risk as required by other safety legislation

 

16 – Other Information

 
 

Compiled according to the CHIP regulations 1994/Amendments 1997.
Further information is available from Firestopit.com

 
 

This data sheet is compiled to be of assistance but is without guarantee. Users are responsible for safe working.

 

  Additional Resources
Datasheet Material Safety Datseheet Test Data

View

Download

View

Download

View
 

 

© 2004