Ablative Boards

Fire Rated Mortar

Pipe Seals

Fire Rated Sealants

Linear Gaps/Joints

Fire Curtain/Pillows

Datasheets          

Installation Details

Safety Datasheets

Test Evidence

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Silverflame Pipe Wrap

Silverflame Pipe Sleeve

BA120 Intumescent Acrylic

Pyrocoustic Intumescent Acrylic

Silverflame ablative Sealant

Stopseal Fire Rated Silicone

Stopseal Putty

Stopseal Linear Gap Seal

Silverflame Expansion Joint

Flameshield Barrier

Stopseal Intumescent Pillows

FSI 101 Acetoxy Silicone

FSI 301 Neutral Silicone

FSI 501 Acrylic Sealant

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Flameshield Barrier

Stopseal Intumescent Pillows

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Silverflame Pipe Wrap

Silverflame Pipe Sleeve

BA120 Intumescent Acrylic

Pyrocoustic Intumescent Acrylic

Silverflame ablative Sealant

Stopseal Fire Rated Silicone

Stopseal Putty

Stopseal Linear Gap Seal

Silverflame Expansion Joint

Flameshield Barrier

Stopseal Intumescent Pillows

Silverflame Ablative Batt

Stopseal Ablative Board

Silverseal Fire Rated Mortar

Stopseal Pipe Collar

Silverflame Pipe Wrap

Silverflame Pipe Sleeve

BA120 Intumescent Acrylic

Pyrocoustic Intumescent Acrylic

Silverflame ablative Sealant

Stopseal Fire Rated Silicone

Stopseal Putty

Stopseal Linear Gap Seal

Silverflame Expansion Joint

Stopseal Intumescent Pillows

Contact firestopit

Distributors

Installers

 
 

technical, test data catalogue

Silverflame Expansion Joint

 

 

 

 

  Silverflame Expansion Joint Test Data

Test Reference

Test Type

Plane

Gap Size (mm)

Seal Outside Diammeter(mm)

Wall Width (mm)

Integrity

LPC CC85398

BS476

Vertical & Horizontal

5-10

11-20

21-30

31-40

41-50

51-60

61-70

71-80

20

26

36

57

69

83

97

104

2.5

3.5

3.5

5

5

5

5

5

120 min

120 min

120 min

120 min

120 min

120 min

120 min

120 min

BTC5359

BS476

Vertical

20

30

50

60

38

38

69

69

6

6

8

8

240 min

240 min

240 min

240 min

LPC CC87369

BS476

Vertical & Horizontal

5 -10

11-20

21-30

31-40

41-50

51-60

61-70

71-80

5 -10

11-20

21-30

31-40

41-50

51-60

61-70

71-80

20

26

36

57

69

83

97

104

20

26

36

57

69

83

97

104

2.5

3.5

3.5

4

5

5

6

6

4

5

6

6

8

8

8

8

120 min

120 min

120 min

120 min

120 min

120 min

120 min

120 min

240 min

240 min

240 min

240 min

240 min

240 min

240 min

240 min

Silvertown G5

40 year life cycle & compression set test

n/a

n/a

Silverflame

Quelfire

Promaseal

Nullifire

suitable

unsuitable

unsuitable

unsuitable

CDL 549

Comparison of Fire Testing

Horizontal

20

30

Silverflame

Quelfire

Promaseal

Nullifire

240 min

240 min

180 min

210 min

Hann Tucker 7452/1

Acoustic Testing

Horizontal & Vertical

10

20

30

40

50

60

70

80

n/a

41 dB

40 dB

40 dB

41 dB

40 dB

40 dB

39 dB

39 dB

 
 
 

  Additional Resources
Datasheet Material Safety Datseheet Test Data

View

Download

View

Download

View
 

 

© 2004